8. Range of programmable parameters
Description Programmable range Default values
LOW (Minimum RPM value
permitted)
500 ÷ 2700 (*) RPM, steps 10RPM 2240
HIGH (Maximum RPM value
permitted)
2000(*) ÷ 5000 RPM, steps
10RPM
2440
BACK (reaction time for
reverse valve)
0 ÷ 2500ms, steps 10ms 300
PULSES (number of
pulses/revolution for RPM)
2.0 ÷ 200.0 pulse/rev, steps 0.1
pulse/rev
129.0
TYPE (reverse function is
ON)
ON or OFF ON
(*) LOW value shall never exceed HIGH value (and vice versa), and priority shall be
given to the LOW value with 20RPMs hysteresis; e.g: if a LOW value is programmed
equal to 1980RPM, the HIGH value shall not be lower than 2000RPM;
Now, by releasing all keys, the monitor operates under standard condition and the
initial test is carried out again.
7. Technical features
Supply voltage 10 ÷ 16 Vdc
Max. current absorption at 16 Vdc (excluding outputs) 200 mA
Protection degree IP 66
Operating temperature range -20 / +70 °C
Storage temperature range -25 / +85 °C
Mechanical vibrations resistance 2 g random
Reference standards for the project MC14982
Autofeed Settings for Carlton Chippers
Engine Make Engine Model HP Rating High Setting Low Setting CAL
Vanguard Big Block V Twin 35 HP 3200 2400 98
Kubota D1105T 33 HP 2440 2370 12
Kohler
CH740
27HP 3330 2900 97.4
Kubota V3300T 88 HP 2440 2370 12
Kubota V3800T 99HP 2440 2370 12
John Deere 99 HP 2440 2240 129
John Deere 140 HP 2440 2240 129
John Deere 6068T 173 HP 2440 2370 129
John Deere 6068H 250 HP 2440 2370 129